Writing a peptide specification annex
“Semaglutide, ≥98%” is a product description, not a specification. This is the field list that turns it into something a laboratory can test and a supplier can be held to — including the three ambiguities that cause most arguments.
Why the annex is the technical document
A purchase contract says what happens if material fails. The specification annex says what “fail” means. If the annex is thin, the contract has nothing to enforce, and every disagreement becomes a negotiation about intentions. The annex should be short enough to read in five minutes and specific enough that two laboratories testing the same lot reach the same verdict.
1. Identity block
| Field | What to state |
|---|---|
| Product name | The name you will use on the label, plus any synonym the supplier uses — aliases are a common source of mismatch |
| Sequence | One-letter code, N→C direction stated, with every non-standard residue and terminal modification written out |
| Molecular weight | The value and whether it is monoisotopic or average; state the calculated value from the sequence, not only the catalogue figure |
| CAS number | Where one exists. A CAS number identifies a substance, not a grade, and does not substitute for the sequence |
| Counter-ion form | Acetate, TFA, HCl, or “as free base”; if a mixture is acceptable, state the ratio or the limit |
| Appearance | Colour and form of the lyophilized cake or powder; add the appearance of the reconstituted solution if you will rely on it |
Identity is the one block where “report” is not good enough. If the annex does not fix the sequence and the salt form, a supplier can ship a materially different molecule that passes every purity limit you wrote. The arithmetic behind sequence-to-mass is covered in sequence and molecular weight; when an intact mass is not enough, MS/MS confirmation is the test to specify.
2. Purity and assay block
This is where most annexes fail, because “purity” is used for at least three different measurements:
- Chromatographic purity (area %) — the target peak as a fraction of UV-absorbing peak area, at a stated wavelength, on a stated method.
- Assay or net peptide content — the mass fraction of the peptide itself, excluding counter-ion, water and residual solvent.
- Impurity profile — individual and total specified impurities, each with its own limit.
A limit of “≥98%” without naming which of these it refers to is not testable. Write the method into the annex: column chemistry and dimensions, mobile phases, gradient, detection wavelength, injection concentration, integration rules and the system-suitability criteria. If the method is the supplier's in-house method, attach the summary; if it is a pharmacopoeial method, cite the monograph and edition. The difference between area percent and mass percent is worked through in reading a chromatogram.
3. The basis-of-calculation problem
The same lot can be “99%” or “82%” depending on the denominator. Three bases are common and they are not interchangeable:
| Basis | Denominator | Typical use |
|---|---|---|
| As-is | Everything in the vial, including water and counter-ion | Weighing and shipping; what you actually receive |
| Anhydrous | Everything except water | Comparing lots where moisture varies |
| Peptide base | The peptide moiety only, counter-ion excluded | Molar calculations and cost-per-mg comparisons |
Put the basis in the annex, next to the number. Then put it in the certificate template too, so the release value and the specification are expressed the same way. A supplier who reports “98.5%” without a basis has told you less than they appear to. The cost consequence is covered in net peptide content and cost per mg.
4. Physical and chemical block
| Field | Method | Why it belongs in the annex |
|---|---|---|
| Water content | Karl Fischer | Affects stability, weighing and the as-is basis |
| Residual organic solvents | Headspace GC, where relevant | Purification residues change handling and smell; some are regulated — see residual solvents |
| pH of reconstituted solution | Stated concentration and solvent | A release check that also predicts handling behaviour |
| Solubility | Stated solvent and concentration | “Freely soluble” without conditions is not a criterion |
| Endotoxin / bioburden | LAL / microbial count | Only if actually performed — never list a limit you do not intend to test |
| Heavy metals / elemental impurities | ICP-MS or compendial method | Relevant where catalysts or metal handling are part of the route |
The endotoxin row deserves emphasis: listing a limit implies a test. If the annex says “endotoxin ≤ X EU/mg” and the certificate never reports it, you have created an unverifiable requirement — worse than omitting it, because it looks controlled. What each test can and cannot show is set out in endotoxin and bioburden and testing methods.
5. Fill, packaging and labelling block
The annex should fix the container closure and the fill, not leave them to the order confirmation. At minimum: primary container and material, nominal fill with tolerance, headspace treatment, desiccant, secondary pack, and the label content for every layer. Packaging choices and their failure modes are covered in packaging configurations.
6. Sampling, retention and documentation
State the sampling plan — how many containers, how the sample is drawn, who holds it — and require a retained sample from the same lot for an agreed period. Then list the documents that must accompany each shipment: certificate of analysis per lot, specification sheet, safety data sheet, packing list and commercial invoice. Make the annex reference the document numbers so a shipment can be checked against it without interpretation.
7. Common omissions that make a limit unenforceable
- No method. A numeric limit without a method is a preference.
- No basis. As-is, anhydrous or peptide base — unstated means the supplier chooses, and they will choose the flattering one.
- No impurity limits. Total purity can pass while a single specified impurity is far above what your work tolerates.
- No units on microbiological limits. EU/mg, EU/mL and EU per vial are different specifications.
- No revision control. An undated annex cannot be referenced in a dispute; give it a version, an effective date and a change log.
- No acceptance criteria for appearance of solution. Visible particles, colour and clarity are cheap to specify and hard to argue about later.
- No reference standard. If purity is measured against an in-house standard, say what it is and how it was qualified.
- Contradiction with the certificate template. If the annex asks for water content but the certificate has no field for it, the requirement will quietly disappear.
8. Keep it alive
A specification annex is a controlled document. Give it a revision number, date every change, and route changes through the same change-control clause as the supply agreement — otherwise a “minor” edit to a limit becomes a silent renegotiation. Review it after the first three lots: the values you wrote before you had data are hypotheses, and the first real certificates are the evidence. If a limit turns out to be unmeasurable at your scale, fix the annex rather than tolerating a permanent deviation.
Editor's take
If it is not in the annex, it is a preference. Acceptance criteria turn 'we expect 98%' into a test a third party can apply — and that is the difference between a standard and a hope.
Sources & evidence
- Specification and analytical expectations: ICH Q6B / Q2(R1) — ICH quality guidelines.
- API manufacturing quality systems: ICH Q7 — same ICH page.
- Chinese national standards: GB/T via the SAMR full-text platform.
Commercial due diligence guidance, not legal advice; supplier claims must be verified against batch documents.
Limitations
This is commercial due diligence guidance, not legal advice. Supplier claims must be verified against batch documents and, where required, an independent audit.
Products referenced in this guide
Related reading & products
- Procurement contract terms — the clauses that sit around this annex
- Net peptide content — the basis-of-calculation problem in money terms
- Counter-ion forms — why the salt belongs in the identity block
- Reading a chromatogram — what a purity method must state
- COA review — checking a certificate against the annex
- Packaging configurations — the fill and container fields
- Sampling and batch release — the plan that decides whether the limit is ever tested
- Batch documentation package — the records that carry the annex through a real lot
- Ordering a custom peptide — the fields to settle before the annex is written